Tap point / distribution area ----------------------------- TAP (class) ^^^^^^^^^^^ .. figure:: ../media/image729.png :figwidth: 0.92708in :align: center Tap point or distribution area **Supplier type** +----------------------------------------+-------------------------------------------------------------------------------------------------------------------------------------------------------------------+--------+ | type label | description | active | +========================================+===================================================================================================================================================================+========+ | Tap return flow | If system head drops below downstream head, tap supplies back to system. | No | +----------------------------------------+-------------------------------------------------------------------------------------------------------------------------------------------------------------------+--------+ | Tap non-return flow | If system head drops below downstream head, tap does not supply back to system. | No | +----------------------------------------+-------------------------------------------------------------------------------------------------------------------------------------------------------------------+--------+ | Tap non-return flow with dP for reopen | If system pressure drops below downstream pressure, tap does not supply back to system. Supply to system (re)starts when a minimum required pressure is exceeded. | No | +----------------------------------------+-------------------------------------------------------------------------------------------------------------------------------------------------------------------+--------+ .. _mathematical-model-35: Mathematical model """""""""""""""""" In steady state the governing equation of this component is very simple: .. math:: Q=-Q_{\mathrm{D}} in which: =========== ============================= =============== Q = system discharge to the TAP [m\ :sup:`3`/s] Q\ :sub:`D` = delivery rate [m\ :sup:`3`/s] =========== ============================= =============== The negative sign appears because of the convention that a flow out of the system is defined negative. After obtaining the steady state solution the head loss coefficient is computed with: .. math:: C=\left(H-H_{\mathrm{D}}\right) / Q^{2} in which: =========== = ======================== ========================= C = head loss coefficient [s\ :sup:`2`/m\ :sup:`5`] H = system pressure head [m] H\ :sub:`D` = downstream pressure head [m] =========== = ======================== ========================= The downstream head is either given by the user or for the Tap non-return flow 2 based on the downstream pressure specified by the user. This head loss coefficient is kept constant throughout the unsteady state computation. The governing equation then is: .. math:: H-H_{D}=C Q|Q| For the **return** type of the tap component equation (3) is valid for positive as well as negative values of *Q*. For the **non-return** type equation (3) is only valid for positive values of *Q*. In case *Q* becomes negative the component changes from H-phase and closes like a check valve. The governing equation the simply is: .. math:: Q=0 The non-return tap opens again if *H* > *H*\ :sub:`D`. For the Tap non-return flow 2 an additional pressure drop can be set which is required to open the tap. Tap return flow ^^^^^^^^^^^^^^^ .. _hydraulic-specifications-40: Hydraulic specifications """""""""""""""""""""""" ===================== ===== ================ ===== ======= ======= Description Input unit range default remarks downstream head Real [Pa] initial delivery rate Real [m­\ :sup:`3`/s] (0-5] ===================== ===== ================ ===== ======= ======= See also "Mathematical model" (:numref:`mathematical-model-35`). .. _component-specific-output-38: Component specific output """"""""""""""""""""""""" None .. _h-actions-36: H-actions """"""""" None .. _component-messages-35: Component messages """""""""""""""""" +------------------------------------------------------------------+-------+---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+ | Message | Type | Explanation | +==================================================================+=======+===================================================================================================================================================================================================+ | System pressure head (... m) is lower than delivery head (... m) | Error | Initially the tap discharge must be out of the system. Since the computed head loss coefficient may not be nega­tive the system pressure head must be higher than the delivery (downstream) head. | +------------------------------------------------------------------+-------+---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+ See also "Mathematical model" (:numref:`mathematical-model-35`). Tap non-return flow ^^^^^^^^^^^^^^^^^^^ .. _hydraulic-specifications-41: Hydraulic specifications """""""""""""""""""""""" ===================== ===== ================ ===== ======= ======= description input unit range default remarks ===================== ===== ================ ===== ======= ======= downstream head Real [m] initial delivery rate Real [m­\ :sup:`3`/s] (0-5] ===================== ===== ================ ===== ======= ======= See also "Mathematical model" (:numref:`mathematical-model-35`). .. _component-specific-output-39: Component specific output """"""""""""""""""""""""" None .. _h-actions-37: H-actions """"""""" None .. _component-messages-36: Component messages """""""""""""""""" +------------------------------------------------------------------+-------+---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+ | Message | Type | Explanation | +==================================================================+=======+===================================================================================================================================================================================================+ | System pressure head (... m) is lower than delivery head (... m) | Error | Initially the tap discharge must be out of the system. Since the computed head loss coefficient may not be nega­tive the system pressure head must be higher than the delivery (downstream) head. | +------------------------------------------------------------------+-------+---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+ | opens | Info | | +------------------------------------------------------------------+-------+---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+ | closes | Info | | +------------------------------------------------------------------+-------+---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+ Tap non-return flow with DP reopen ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ .. _hydraulic-specifications-42: Hydraulic specifications """""""""""""""""""""""" ===================== ===== ================ ===== ======= ======= description input unit range default remarks ===================== ===== ================ ===== ======= ======= downstream pressure Real [Pa] initial delivery rate Real [m­\ :sup:`3`/s] (0-5] Delta P for reopen Real [Pa] ===================== ===== ================ ===== ======= ======= See also "Mathematical model" (:numref:`mathematical-model-35`). .. _component-specific-output-40: Component specific output """"""""""""""""""""""""" None .. _h-actions-38: H-actions """"""""" None .. _component-messages-37: Component messages """""""""""""""""" +----------------------------------------------------------------------+-------+------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+ | Message | Type | Explanation | +======================================================================+=======+======================================================================================================================================================================================================+ | System pressure (... barg) is lower than delivery pressure (...barg) | Error | Initially the tap discharge must be out of the system. Since the computed pressure loss coefficient may not be nega­tive the system pressure must be higher than the delivery (downstream) pressure. | +----------------------------------------------------------------------+-------+------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+ | opens | Info | | +----------------------------------------------------------------------+-------+------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+ | closes | Info | | +----------------------------------------------------------------------+-------+------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+ .. include:: substitutions_liquid.rst